Annex F

(Normative)

Graphic Representation Option

F.1 Introduction

This annex contains an option which allows the use of Graphic Representation modules. Unless stated otherwise in this annex, all requirements of the body of this part also apply when using this option.

F.2 Spatial Objects

This option does not add any additional permitted spatial object types.

F.3 Transfer Module Specification

The following table contains inclusion/exclusion, and cardinality rules for additional modules permitted by this annex. The standardized modules names are included, along with the minimum number and the maximum number of occurrences of the module type. A lowercase "n" indicates that the upper limit is user defined. Any lowercase letters or dots in the module name has the meaning explained in Section 4, Standard Module Names.


Module Type


Name


Min. No.


Max. No.


Text Representation


TEXt


0


n


Line Representation


LNRp


0


n


Symbol Representation


SYRp


0


n


Area Fill Representation


AFIl


0


n


Color Index


CLRx


0


n


Font Index


FONt


0


n

F.4 Module Restrictions/Requirements: Identification Module

To indicate that this annex is being used, the Profile Identification subfield shall include "/F" in the manner described in section 5.8.2 of Part 4.

F.5 Module Restrictions/Requirements: Catalog/Cross Reference Module

If there is more than one Font Index or Color Index module, entries in the Catalog/Cross Reference module shall be used to indicate which Font Index module is referenced by each Text Representation module and which Color Index module is referenced by each Text Representation, Line Representation, Symbol Representation, and Area Fill Representation module. A module may not reference more than one Font Index or Color Index module.